Changing the worktable

  • Place toolhead in convenient position before removing worktable.

IMG_5975.jpg


Note: The user can move the toolhead manually by disabling the motors by: 

  • pressing the reset button,
  • powering down the machine,
  • parking the toolhead in the 'Change toolhead' section,
  • waiting 1 minute for the standby mode.

  • Slide the table backwards,

IMG_5976.jpg

  • Disconnect the table plug,

IMG_5977.jpg

  • Pull the worktable forward,

IMG_5978.jpg

  • Pull the lever placed on the left to unlock the heated table,

IMG_5979.jpg

  • Lift the table with a little bit of strength up to disconnect it from the carriage magnets,

IMG_5980.jpg

  • Take the CNC table. Notice if the magnets under the table are on the proper side,

IMG_5981.jpg

  • Place the worktable on the carriage, magnets will clip it on,

IMG_5984.jpg

  • Pull the lever back to block the table,

IMG_5983.jpg

  • Make sure that lever doesn’t block the table movement by pulling the table forward.

IMG_5982_-_Kopia.jpg

 

 

 

 

 

Have more questions? Submit a request